HOME PRODUCTS CASE HISTORIES FAQ NEWS CONTACT US



Thin Film Technology -- Case History - 37

BIO-FLOR™ 182 SEAMLESS EPOXY FLOORING SYSTEM SEALS AND PROTECTS THE FLOOR OF A LARGE BREWERY FILTERING ROOM.


THE CHALLENGE: A large East Coast brewery required a seamless coating to protect the freshly poured concrete floor of its filtering room. The coating was required to be tough, durable and completely resistant to beer, fermentation liquids and powerful cleaning chemicals.

THE SOLUTION: The Owner chose Encap, Inc. for the application because of very favorable previous experiences. Encap, Inc. recommended BIO-FLOR™ 182 because of their extensive earlier experience with the product and its availability in the specified "Signal Red" color.

The entire horizontal floor was abrasive blasted with a ėBlastracî type centrifugal walk-behind blast unit then coated with a base coat of BIO-FLOR™ 182. Clean, sharp quartz was broadcast into this BIO-FLOR™ 182 base coat to the point of rejection. When completed this results in the entire floor appearing as dry sand showing no visible trace of the underlying coating. The floor is left in this condition for at least four hours during which time the sand sinks through the uncured BIO-FLOR™ 182 film forming an incredibly hard and tough coating. After four hours the BIO-FLOR™ has cured sufficiently to allow applicators back onto the floor to sweep off the unabsorbed sand. This is accomplished using regular stiff brooms; recovered sand or other abrasive may be "recycled" for future use by passing it through a window screen or similar mesh sieve.

After removal of the excess abrasive, the floor appears as a very uniform and attractive surface; however, before completion, it is required to be sealed by the application of a second BIO-FLOR™ 182 coat. This application permanently seals in loose surface grains and presents a shiny, textured coating which is easily cleaned yet quite slip resistant under wet conditions.

BIO-FLOR™ 182 was ideal for this application for several reasons

  • Easy 2/1 mix ratio
  • Rapid cure rate which allows a complete system to be installed, and cured for service, in 24 hours.
  • BIO-FLOR™ 182 has almost no odor. Applications of over 7,000 sq.ft. per day immediately adjacent to other trades in large Government facilities have been made regularly with no odor complaints.
  • Application is made using conventional paint rollers and brushes. These tools eliminate the hazardous aerosol of epoxy coatings generated when applied by spray in a confined space.

RESULT: The completed floor is extremely attractive and is functioning well. Regular cleaning by hosing and mopping is easily accomplished using normal Plant procedures.

For more information regarding this successful project contact:

Jeff Longmore,
Thin Film Technology, Inc.;
Tel (713)910-6200; Fax (713)910-6210
E-mail: jeff@thinfilmtech.net

     

Return to Articles Homepage   |   Return to 'Case Histories' Category